Philip Morris
Near Infrared Reflectance Analyses (Nira) 880700 - 880900
Fields
- Litigation
- STMN/PRODUCED
- Master ID
- 2028635453/5604
- 2028635453-5604 Quarterly Report 880700 - 880900
- 2028635458-5459 Microbiological Analyses 880700 - 880900
- 2028635460-5465 Europ 880700 - 880900
- 2028635466-5470 Aquarius 880700 - 880900
- 2028635471-5476 Pesticides 880700 - 880900
- 2028635477-5479 Deimos 880700 - 880900
- 2028635480-5481 Rhea 880700 - 880900
- 2028635482-5484 Hydra, Ets 880700 - 880900
- 2028635487 Order 880700 - 880900
- 2028635488-5489 Orion 880700 - 880900
- 2028635490-5493 Pack 880700 - 880900
- 2028635494-5497 Analytical Investigations 880700 - 880900
- 2028635499-5500 Caiman 880700 - 880900
- 2028635501-5502 Courbet 880700 - 880900
- 2028635503 Dali 880700 - 880900
- 2028635504 Degas 880700 - 880900
- 2028635505-5509 Miniprimary 880700 - 880900
- 2028635510-5511 Picasso 880700 - 880900
- 2028635512-5513 Pissarro 880700 - 880900
- 2028635514-5516 Tobacco Process Quality (Giotto) 880700 - 880900
- 2028635517 Toyo 880700 - 880900
- 2028635518 Trial Etb / FTR 880700 - 880900
- 2028635519-5521 Turner 880700 - 880900
- 2028635522-5523 Velasquez 880700 - 880900
- 2028635524-5528 Test Report Strips / Stem Processing and HT-Expansion With the Hauni HT-Conditioner
- 2028635529 Weasel 880700 - 880900
- 2028635531-5534 Product Innovation 880700 - 880900
- 2028635535-5538 Product Innovation 880700 - 880900
- 2028635539-5542 Cigarette Development Eec 880700 - 880900
- 2028635543-5545 Cigarette Development Eema 880700 - 880900
- 2028635546-5549 Flavour Development 880300 - 880900
- 2028635550-5555 Studies and Modelling 880700 - 880900
- 2028635557-5559 Material Testing 880700 - 880900
- 2028635560-5565 Cigarette and Smoke Analysis 880700 - 880900
- 2028635566-5568 Tobacco Monitoring 880700 - 880900
- 2028635569-5575 Analytical Services 880700 - 880900
- 2028635576-5577 Visual Quality Audit 880700 - 880900
- 2028635578-5579 Subjective Cigarette Evaluation 880700 - 880900
- 2028635580-5581 Infestation Control 880700 - 880900
- 2028635582-5583 Quality Engineering 880700 - 880900
- 2028635585-5586 Ingredients, Casing & Flavors 880700 - 880900
- 2028635587 Foam Binding 880401 - 880725
- 2028635588-5590 Ingredient and Material Evaluation 880700 - 880900
- 2028635591-5593 Materials Trials: Concept 880000 and Achievements
- 2028635594-5596 Product Modifications (Licensees) 880700 - 880900
- 2028635597-5598 Product Monitoring and Changes (Affiliates) 880700 - 880900
- 2028635600-5603 Computer Applications 880700 - 880900
Related Documents:
Document Images
RESEARCH AND DEVELOPMENT, NEUCHATEL - QUARTERLY REPORT
DIVISION RESEARCH
SUBJECT TITLE . NEAR INFRARED REFLECTANCE ANALYSES (NIRA)
PERIOD COVERED : JULY - SEPTEMBER'1988
WRITTEN BY . Moser-F. (FMO)
KEYWORDS . infraAlyzer, nira, flavor
OBJECTIVE
To evaluate Near Infrared Reflectance Analyses (NIRA) as an
anlytical approach towards routine quality and/or process control
measurements.
STATUS
An infraAlyzer method for the determination of main components in
flavors MF-AC-B'ase and MFSB-1 liquid is being developed.
Calibrations for ethanol, water, fructose and glucose in~MF-AC
flavor, and ethanol, water and propylene glycol in I-IFSB flavor
were established. For each type of flavor, specific calibrations
have to be made, e.g. the calibration for ethanol in MF-AC cannot
be used to determine ethanol in MFSB. Whether the total composi-
tion of a flavor and not only the main components or in the case
of P?FSB.propylene glycol is the reason for this effect is not yet
known.
To check the reproducibility of the infraAlyzer measurement with
the liquid cell the 4 components in a MF-AC sample were
determined twelve times. The resulting CV-values (%) are :
Ethanol 1.27, water 0.38', fructose 1i.13 and glucose 0.97.
In order to check the validity of the calibrations, 10 MF-AC and
6 MFSB' samples were measured andithe infraAlyzer values of the
various components compared with the lab values from PM-Richmond
and/or QA-PME. All infraAlyzer values were found to be in good
agreement with the lab values.

RESEARCH ANDDEVELOPMENT, NEUCHATEL - QUARTERLY REPORT'
PLANS
Since the number of samples for the calibrations was relatively
small, the check of validity will continue.