Jump to:

Filter Ventilation and Design

Subject: Nicotine and TPM Availability with Filter Dilution.

Date: 10 Feb 1972
Length: 2 pages
1003455619-1003455620
Jump To Images
snapshot_pm 1003455619-1003455620

Abstract

Reports on experiment to "determine whether the increase in nicotine-to-TPM ratio with increasing filter dilution is caused by a filter phenomenon or by a rod phenomenon." Finds that a rod phenomenon is responsible for the increase.

Fields

Type
Memorandum
Chart/Graph/Table
Company
Philip Morris
Site
R16
Author
Geiszler, W.A.
Recipient
Claflin, W.E.
Copied
Osmalov, J.S.
Lendvay, A.T.
Resnik, F.E.
Thomson, R.N.
Named Person
Lendvay, A.T.
Thesaurus Term
Tar Level
Nicotine Level
Filter Ventilation

Document Images

Text Control

Highlight Text:

OCR Text Alignment:

Image Control

Image Rotation:

Image Size:

Page 1: fdi28e00
PHILIP MORRIS U.S.A. NTER-OFFICE CORRESPONDENCE Nicotine and TPM Availability with Filter Dilution. results show that the increase originates in the rod-. caused by a filter phenomenon or by a rod phenomenon. The An experiment was run to determine whether the increase . in nicotine-to-TPM ratio with~ increasing filter dilution is very slightly with increasing dilution: As shown below, filter efficiency for each~component drops .Nicotine and TPM filtration efficienc ies were determined ~ for Monitor #14 filters having 0, 22, and 42% filter dilution. < Available nicotine and TPM were calculated as the sum S increase in nicotine-to-TPM ratio. 0% 22% 42% Filtration Effic ienc Nicotine TPM 3 7% 4 3% 36% 43% 35% 42% .These slight changes in efficiency cannot account for the ~of that removed by the filter plus that delivered to the Cambridge pad for each component. The "available" and "delivered" dilution in the same manner as the "available" ratio. (The .The "delivered'" ratio is found to respond to increased filter ,:nicotine-to-TPM ratios are plotted versus dilution in Figure 1. .correlates with the filter dilution effect described'here. :< O machine causes an increase in the nicotine-to-TPM ratio, which O' Lendvay has found that reducing puff volume on the smoking -. ~-b : in nicotine-to-TPM ratio w ith increased filter dilution. A. T. likely a coal phenomenon -- is responsible for the increase nicotine-to-TPM ratios shows that a rod phenomenon -- most . __for TPM.) The agreement between "available" and "delivered"_- filter efficiency is only 35-37% for nicotine versus 42-43% "delivered" ratio is higher than the "available" ratio because /ad Mr. F. E. Resnik Mr R N! Thomson . . . Mr. J. S. Osmalov J ~~ Mr. A. T. Lendvay Filter Dilution .
Page 2: fdi28e00
rJpE 10 X 10 TO THE INCN 46 0700 Il 7 X IC INCr[B ++o\ ~+ u.~.(. KLVFPEL i ESfER Co. ... .r .. . - -, '. . ' . ~ . ~ . . . . .. ar.. ~~~~. . . "~_,.\ , _ _- . ..._ -- _._- - . _ - _ . . - • -. _ a _ ._ • - -- _ _ : _.._ . - - 1 - . _ _ _ - - -- -- - - -- - - - - - - - - - - - - - - ~ - - _ - - - - - - - - - - _ - _ - -- - f - , - -- -- - -- __ E ' - - - -- - - -t - - - - - - -' ~-~ ~- - _ -- - --- - _ ~ 1 f = _ _ i f LE -- _ 4 ~ 4 T t- j e TT ; 1- ~a•~' ,•,_; T ~ . ~ ~ ~ --~. - ~ -- IT - 1 I ! - f ~ ~ J ~ ~ f- ~1 1 . _ - - 1 _ I 1 - ~ ~ ! k ~ _ I ~ _ ~ . ~ _I ` _ ~~ - _ - _ _ ~ ~ r 1y ~ i ! ~ r _ ~ + :`. } f r~ t i f l : _ -- _- - - - - - - , _- - _ _ _ ~ _ - -, __ - _ - - l A- l -; - - - -- - - - - o%9ssvEOOZ r