MODEL
PROTOCOL
FOR
SURVEY
OF
INDOOR AIR QUALITY,
VENTILATION, AND
SMOKING ACTIVITY
IN RF~TAURANTS
Hoy Bohanon
Environmen~ Affairs Department
R. J. Reynolds Tob~co Co.
REVISED September 1, 1995
AQ10441
O

9~0 ,'al 2953
09..01.'9S IS:28 '~910 741 2963 ~OO~
Executive Summm~
Evaluations of Indoor air quality are planned for restaurants where smoking is permit~ed.
Those evaluations ~re being done ~n order to provide scientific and ~ohnical infon'aation
on the relationships between five variables: location, ventilation and filtration systems,
occupant perception, smoking rates, and concentrations of Indicators of indoor air quality
and environmental tobacco smoke. This protocol represents one aspect of the planning
process which has as its goal the assurance that the objectiws of the evaluations are met.
This document describes the specific objectives of ~h˘ evaluations, organizations involved,
and methods of sampling and analysis.
O
AQ10441

910 7~1 2963
o9.'oi.~ i.~27 ~9io 74i 2963 ~oo4
Table of Contents
1. PROJECT OBJECTIVES 1
2. DESCRIPTION OF PROJECT 1
3. PARTICIPATING ORGANIZATIONS 2
3.1 ...... Personnel
2
3.2 ........ Corporation
3
4. BUILDINGS
5. DESCRIPTION OF PROCEDURE FOR SELECTING SAMPUNG SPACES
3
6. PROCEDURE FOR SELECTING SAMPLING LOCATIONS IN SPACES
4
7. QUALITATIVE ASBESSMENT OF VENTILATION SYSTEM
4
7.1. Mechanical Ventilation
4
7.2. Natural Ventilation
8. DETERMINATION OF OUTSIDE AIR QUALrrY
8.1. LOCAL AMBIENT MONITORING STATION DATA ON AIR QUALITY
5
g.2. i˘SP
6
8.3. UVPM
8.4. FPM
6
8.5. Solantsol
6
8.6. Carbon Monoxide
6
8.7. Carbon Dioclde
8.8. Temperature and Relative Humidity
6
9. DETERMINATION OF INDOOR AIR QUALITY
7
9.1. RSP
7
AQ10441
0')
0
0
0

~]oo~5
9.2. UVI'M
9.3. FPM
9.4. Solane~
9~. Carbon Monoxide
9~. Carbon Dioxide
9.7. Tempera~re ~md Relative HumldiCy
9.8- Nicotine
9.9.3.EP
10. DETERMINATION OF SMOKING ACTIVITY
10.1. Method 1 - Collect Cigarette Butt~ And Count Every 30 Minntea
10.2. Mefllod 2 - V~mlly Assess The Nmabcr Of People Smoking Every ~O Minute~
11. DETERMINATION OF OCCUPANCY OF TEST SPACE
7
7
7
7
8
8
8
12. DETERMINATION OF QUANTrTY OF OUTSIDE AIR SUPPUED TO TEST
SPACES 9
12.1. Method 1 - Have Test And Balance (T&B) Engineering Con~Itaat Measure hWAC Aad
Establish A Ventilation Rate
9
12,2. Method 2 - Use CO2 Measurementa Along With Counts Of People In ~ Space To Estimate
Air Exchange Rates
12.3. Method 3 - Use Tracer Gas To Determine Air Exchange Rater
13. INDOOR AIR QUALITY QUESTIONNAIRE
14. SCHEDULING
15. ANALYSIS
9
10
11
12
9/I/95
AQI044|
O
O

9LO 74~. 2965
09:01/9.$ 1.~:Z8 ~'910 141 2983
~006
RESTAURANT TEST PROTOCOL
1. Project Objectives
The nhjcctives of the project me as follows:
(a) To survey restaurants in several different countries of the world.
(b) To determine acceptability of indoor air conditions as judged by occupants
of the restaurant space.
To assess concentrations of environmental tobacco smoke (ETS) present in
the selected spaces.
(d) To appraise the ventilation system including operation and maintenance
(O&M) of heating, ventilating, and air conditioning (I-WAC) systems and
estimate outdoor Mr ventilation rates.
(e) To determine smoking rates in the re.~taurant~ observed.
(f) To develop correlation between the smoking rates, ventilation rates, ET$
concentrations, and occupant perceptions of restaurant indoor air quality.
2. Description of Project
The purpose of this project is to survey restaurants where smoking is allowed in multiple
countries. The hypothesis is that most restaurateur~ operate their restaurants in a manner
such that 80% or more of the patrons perceive the air quality to be acceptable.
This model protocol will be used for all tests. Tests will Ix~ conducted by participating
companies in their respective countries. It will be modified for each country by
determining the participating organizations (Section 3). specifying the equipment to be
used (Sections 8 & 9), and tnmslating the questionnairB ($~'tton 13) into the native
Ira1 guage..
Evaluations will be conducted in restaurants located in different buildings The identified
factors are smoking rate, ventilation assessment, ETS concentration and occupant opinion.
PR OTOCOL.DOC 1
9/1/95
AQ10441

91.0 ,'~. 2_96~
09/01.'95 1~:28 ~910 741 2963
~007
RESTAURANTTEST PROTOCOL
At each bui]ding the evaluation will occur over two consecutive days and will entail
determining the following in the same time frame:
(a) quality of out~ide air supplied to
quantity of outside air supplied to space;
(b) physical dimensions of space;
(c) number of occupants in space;
(d) number of cigarettes smoked in space;
(e) quality of indoor air in space; and
(f) occupant response
3. Participating Organizations
Personnel with the ~ Tobacco Company will be rempomible for overall administration
of the project. Departments involved in the effort include Research a~d Development
(R&D), and Engineering.
Individuals and their specific reqmnsibilides are stmamarizeA below.
3.1. _ ~ Personnel
Mr. will be principal investigator (PI) resgonsible for th~ overall taehnieal and
administrative dhection of the project.
Mr. will be responsible for all efforts dealing with (a) quantifying the numbe,
of cigarettes smoked and the number of occupants and (b) prepanng written reports
addressing data from these efforts, Finally, he will be responsible for assisting with (a) the
~eview of data, results, and statistics, and (b) the preparation of the final report on the
project.
Mr. ~__ will be respons~le for all efforts pertaining to (a) quantifying ventilation
rates and (b) preparing written reports addrcsslng data from these efforts. In addition, he
will be responsible for assisting with (a) the review of data, results, and statistics, and (b)
the preparation of those sections of the final report on the project that have to do with the
HVAC systems and quantification of ventilation rates.
Mr. __ will be responsible for obtaining ambient air quality data repotted by the
Local Department of Environment for times I~rtixmnt to the investigations.
Mr. will be rv~Ton~ible for conducting ~tly~s of r~spirabl˘ suspendM
particles (RSP), ultraviolet particulate matter (UVPM), fluore~nt partlculam matter
(FPM) and solmcsol and for reporting results of these analyses.
PROTOCOL.DOC 2 9/1/95
AQI0441

91D 74~ 2963
09.'01,'~.-3 1.5:29 '~'911) 7~1 2~S,9
RESTAURANT TEST PROTOCOL
I~008
Mr. will b˘ responsible for conduc~g ~alys~s of nico~ne and 3-E~ end for
re.po~ing results ot these analyses.
Mr. will be responsible for preparing and providing the constant flow sampling
pumps for the ev',duadon as well as the impaetors needed for the determinations of
particles.
Mr. will be responsible for performing statistical aaalyses on the data, writing
necessary reports on these analyses, and assisting with the preparation of those sections of
lhc fina~ report on the project that deal with statistical issues.
Mr..~ will be responsible for ensuring that test teams have access to locations in
the buildings. He will coordinate details with the owners and managers of the subject
establishments.
will be responsible for administering questionnaires.
3.2. Corporation
Corporation will be responsible for conducting all tests to quantify ventilation
4. Buildings
A minimum of five restaurants in different buildings will be tİsted. The buildings and
restaurants will be selected to represent a dive~e cross section of the dining
establishments in the community. The restaurants and buildings themselves should be
photographad. An effort should be made to quantify the total building area and the area
occupied by the restaurant. The building ventilation sysmrm mad their operation should
also be documented.
5. Description of Procedure for Selecting Sampling Spaces
Where restaurants contain multiple dining spaces the uanpling spaces within the restaurant
shall be selected givh~g consideration to smoking activity, accessibility, owner's concerns,
and how representative the space is of the overall r~staurant environmont.
Where there are designated sections for smokers and for nonsmokers, one space shall be
selected in each section.
PROTOCOL.DeC 3
911D5
AQ10441
O
O

91.0 ?z~1. 2965
09.'01,95 15:29 ~910 741 298~
~009
RESTAURANT TEST PROTOCOL
6, Procedure for Selecting Sampling Locations in Spaces
The. guid~liaes below will be observed to select the specific points within the restaurants
wh~re samples will be colle, ct~d.
(a)
Sumpling poims will be within the "breathing zone," which is defined hem
as that region within an occupied space between planes 0.6 meters and 1.8
meters above the floor and more than 0,6 met˘rs from the walls or fixed
air-conditioni.g equipmcnL (This g~id˘]i~˘ defines a space, which,
although smaller, is pracdcagy the same as ASHRAB's "occupied zone":
"the region within an occupied space between planes 0.08 meters and 1.8
meters .... above the floor sad more than 0.6 meters ... from the walls or
fix'-.d air-conditioning equipment.")
(b) Sampling points should not be susceptible to the direct influence of sources
of ventilation,
(c)
Sampling points should not b˘ susceptible to the direct influence of either
sidestm,'un or mainstream smoke nor should the sampling points be located
in known dead zones or eddies.
Sampling points should be selected in order to minimiz= (to the extant
practical) the effect of the sampling operation on th, ordinmy behavior of
occupants in the selected spaces.
The principal investigator and the restaurant manager will be collectively responsible for
selecting the location within each space based upon their judgment of the criteria above,
It is expected that typical locations will include the horizontal surfaces of tables or
dividers.
7. Qualitative Assessment of Ventilation System
Restaurants can either be mechanically ventilated or naturally ventilated.
7.1. Mechanical Ventilation
witl inspect the HVAC system to assess its operation and maintenance (O&M)
status. This inspection is intended to provide qualitatlv˘ information which will
complement quantitative information from other tests. In addition, this asscssnmnt of
O&M will re.end in part to an issue raised in the ASHRAE Standard:
PROTOCOL,DOC 4
~lD5
AQ10441
O3
0
0
,--.%
0

i~OlO
RESTAURANT TEST PROTOCOL.
It must be recognized, however, that the conditions specified by this
Standard must b~ achieved during the operation of buildings as well as in
the design of the buildings if a~ceptable indoor air quality is to be achieved.
Inspection will includc the following-
(a) assessrncnt of the cleanliness, opcr, gion, and structural integrity of
the intexnals (including filters, coils, distribution boxes, etc.) of the
HVAC systems: and
(b) assessment of the adequacy of the I-IVAC system's design and
O&M to meet the indoor air quality requirements of the space it
selves.
(c) ~ssment of the accss~lity to techmc~l equ~pmem lo~ated h~ l~e
interior of HVAC ~ystems to ensure that the cleaning interwls are
properly resl~ected-
7.2. Natural Ventilation
In situations where there is no mechanical ventilation system, the natural ventilation
s)'str.m components must be documented. The settings of the natural ventilation ~sterns
must. bc docurncxnied during the test.
8. Determination of Outside Air Quality
The quality of the outside air will be determined in accordance with ASHRAE 62-1989,
Section 6. I. 1 Acceptable Outdoor Air.
A number of additional me.~umments will supplement the evaluation of the outside
and complement to the extent practical the measurements of the indoor air. These
identified below. Note that concentrations of respirable suspended particles (mass median
diameter less than 2.5 l, tm) will be determined rather than either total suspended particles
(.TSP) or PM l 0
8.1. LOCAL AMBIENT MONITORING STATION DATA ON AIR
QUALITY
ASIIRAE Standard, Section 6.1.1 Acceptable Outdoor Air gives as one condition for
ensuring that outdoor air is acceptable the use of "monitoring dam of govemmİnt
pollution control agencies, such as the U.S. Environmental Protection Agency (EPA) or
cqtdvalent state or local environmental a protection authorities, show that the air quality of
the area in which the ventilation system is located meets the requirements of Table I [in
ASFIRAE Standard 62- I959]."
PROTOCOL.DeC 5 ~ID5
AQI0441
0
0
0

9/.0 ?4j 296.3
09/0t,'95 15:~0 "~910 741 2S63
RESTAURANT TEST PROTOCOL
~]011
To assess whether the outside a~r is acceptable, concentration data for total suspended
particles (TSP), sulfur dioxide, n~rogen d/oxide, ozone, lead, ~d carbon monoxide from
measnrements of smbient air quality done by the local pollution control agency will be
obtained to supplement results from determinations of the quality of air supplied to the
building.
&2. RSP
Concentrations of RSP will be determined by the method described by Conner et al.
Samples will be collected for at least four hours during testing.
8.;I. UVPM
Concentrations of UVPM will be determined by the method described by Conner et al,
Samples will be collected for at least four hours during testing.
8, 4, FPM
Concentrations of FPM will be determined by the method described by Ogden et 02. This
analytical method utilizes the same sample as that collected for the determinations of RSP
and UVPM described above.
8.5, Solanesol
Co,~centrations of solanesol will be determined by the method described by Ogden et aL
This analytical method utilizes the same sample as that collected for the determinations of
RSP and UVPM described above.
8.6. Carbon Monoxide
Concentrations of" CO will be determined with a National Draeger F.colyzer Model 211
(200 Series) carbon monoxide monitor. Two-minute determinations will be made at three
times during the testing.
8.7. Carl~on Dioxide
Concentrations of CO2 will be determined with a Telair˘ model 1050. This monitor uses a
non-dispersive infrared measurement principle. Two-minute determinations will be made
at three times during the testing. These determinations will occur once prior to beginning
indoor testing, once during the indoor testing and once following the indoor testing.
8.8. Temperature and Relative Humidity
Temperature and relative humidity (RI-I) will be determined with a Telog R-2126
tumperature and humidity ~˘order.
PROTOCOL.DOC 6
9/1/95
AQ10441